目录
输入和输出集成概述
Modbus 插件允许您使用各种通信方法从 Modbus 设备收集数据,从而增强您监控和控制工业流程的能力。
Loki 插件允许用户将日志发送到 Loki 进行聚合和查询,从而利用 Loki 高效的存储能力。
集成详情
Modbus
Modbus 插件通过 Modbus TCP 或 Modbus RTU/ASCII 收集离散输入、线圈、输入寄存器和保持寄存器。
Loki
此 Loki 插件与 Grafana Loki 集成,Grafana Loki 是一个强大的日志聚合系统。通过以与 Loki 兼容的格式发送日志,此插件可以高效地存储和查询日志。每个日志条目都以键值格式结构化,其中键表示字段名称,值表示相应的日志信息。按时间戳对日志进行排序可确保通过 Loki 查询日志流时,日志流保持时间顺序。此插件对密钥的支持使安全管理身份验证参数变得更加容易,而 HTTP 标头、gzip 编码和 TLS 配置选项增强了日志传输的适应性和安全性,从而满足各种部署需求。
配置
Modbus
[[inputs.modbus]]
name = "Device"
slave_id = 1
timeout = "1s"
configuration_type = "register"
discrete_inputs = [
{ name = "start", address = [0]},
{ name = "stop", address = [1]},
{ name = "reset", address = [2]},
{ name = "emergency_stop", address = [3]},
]
coils = [
{ name = "motor1_run", address = [0]},
{ name = "motor1_jog", address = [1]},
{ name = "motor1_stop", address = [2]},
]
holding_registers = [
{ name = "power_factor", byte_order = "AB", data_type = "FIXED", scale=0.01, address = [8]},
{ name = "voltage", byte_order = "AB", data_type = "FIXED", scale=0.1, address = [0]},
{ name = "energy", byte_order = "ABCD", data_type = "FIXED", scale=0.001, address = [5,6]},
{ name = "current", byte_order = "ABCD", data_type = "FIXED", scale=0.001, address = [1,2]},
{ name = "frequency", byte_order = "AB", data_type = "UFIXED", scale=0.1, address = [7]},
{ name = "power", byte_order = "ABCD", data_type = "UFIXED", scale=0.1, address = [3,4]},
{ name = "firmware", byte_order = "AB", data_type = "STRING", address = [5, 6, 7, 8, 9, 10, 11, 12]},
]
input_registers = [
{ name = "tank_level", byte_order = "AB", data_type = "INT16", scale=1.0, address = [0]},
{ name = "tank_ph", byte_order = "AB", data_type = "INT16", scale=1.0, address = [1]},
{ name = "pump1_speed", byte_order = "ABCD", data_type = "INT32", scale=1.0, address = [3,4]},
]
Loki
[[outputs.loki]]
## The domain of Loki
domain = "https://loki.domain.tld"
## Endpoint to write api
# endpoint = "/loki/api/v1/push"
## Connection timeout, defaults to "5s" if not set.
# timeout = "5s"
## Basic auth credential
# username = "loki"
# password = "pass"
## Additional HTTP headers
# http_headers = {"X-Scope-OrgID" = "1"}
## If the request must be gzip encoded
# gzip_request = false
## Optional TLS Config
# tls_ca = "/etc/telegraf/ca.pem"
# tls_cert = "/etc/telegraf/cert.pem"
# tls_key = "/etc/telegraf/key.pem"
## Sanitize Tag Names
## If true, all tag names will have invalid characters replaced with
## underscores that do not match the regex: ^[a-zA-Z_:][a-zA-Z0-9_:]*.
# sanitize_label_names = false
## Metric Name Label
## Label to use for the metric name to when sending metrics. If set to an
## empty string, this will not add the label. This is NOT suggested as there
## is no way to differentiate between multiple metrics.
# metric_name_label = "__name"
输入和输出集成示例
Modbus
- 基本用法:要从单个设备读取数据,请使用设备名称和 IP 地址配置它,指定从站 ID 和感兴趣的寄存器。
- 多重请求:您可以通过指定多个
[[inputs.modbus.request]]
部分来定义多重请求,以从单个配置中的不同 Modbus 从站设备获取数据。 - 数据处理:利用缩放功能将原始 Modbus 读数转换为有用的指标,并根据需要调整单位转换。
Loki
-
微服务的集中日志记录:利用 Loki 插件收集 Kubernetes 集群中运行的多个微服务的日志。通过将日志定向到集中的 Loki 实例,开发人员可以监控、搜索和分析来自所有服务的日志,从而更轻松地进行故障排除和性能监控。此设置简化了操作,并支持对分布式应用程序中的问题做出快速响应。
-
实时日志异常检测:将 Loki 与监控工具结合使用,以实时分析日志输出中可能表明系统错误或安全威胁的异常模式。在日志流上实施异常检测使团队能够主动识别和响应事件,从而提高系统可靠性并增强安全态势。
-
通过 Gzip 压缩增强日志处理:配置 Loki 插件以利用 gzip 压缩进行日志传输。这种方法可以减少带宽使用并提高传输速度,这在网络带宽可能受限的环境中尤其有利。它对于高容量日志记录应用程序特别有用,在这些应用程序中,每个字节都很重要,并且性能至关重要。
-
通过自定义标头支持多租户:利用添加自定义 HTTP 标头的功能来隔离多租户应用程序环境中不同租户的日志。通过使用 Loki 插件为每个租户发送不同的标头,运营商可以确保正确的日志管理并遵守数据隔离要求,使其成为 SaaS 应用程序的通用解决方案。